Configuration using Web Based Management and Command Line Interface
4.7 The Router menu (SCALANCE X414-3E)
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
297
Updates
Number of routing table calculations
LSA Cnt
Number of LSAs in the LSDB of this area
Area BR
Number of reachable area border routers (ABR) within this area
ASBR
Number of reachable autonomous system border routers (ASBR) in this area.
Creating a new OSPFv2 area
With the "New Entry" button in the "OSPFv2 Areas" dialog, you can create a new area.
Figure 4-137 OSPFv2 Area Configuration
Area ID
Enter the ID of the area here.
Area Type
The following area types exist:
Standard
Stub
NSSA
Note
For the backbone area, the selected area type must be "Normal" and the area ID 0.0.0.0.
Import Summary
Note
The "Import Summary" check box is displayed only when the "Stub" area type was set.