PROFINET IO functionality
6.3 Access options over PROFINET IO
SCALANCE X-300 / X-400
338 Configuration Manual, 10/2014, C79000-G8976-C187-22
X308-2M slot functions
the IE switch X308-2M has 3 slots. The fixed slots are assigned to slot 0. The other slots,
each with 2 ports, are assigned to slot 1 and slot 2.
Functions that cannot be assigned uniquely to a port are assigned to the Device Access
Point (slot 0).
Slot 0 Subslot 1
Alarms
Data records (4.5)
Device Access Point (DAP)
Interface connection
C-PLUG
Redundant power supply
Subslot 8001 - 8004
Alarms (IEC)
Data records (IEC)
Switch port 1 - 4
Alarm response
Port state
Slot 1;
slot 2
Subslot 8001 - 8002
Alarms (IEC)
Data records (IEC)
Switch port 5 - 6;
Switch port 7 - 8
Alarm response
Port state
Slot functions of the XR324-12M
The IE Switch XR324-12M has several slots (slot 1 - slot 12) each with 2 ports.
Functions that cannot be specifically assigned to a port are assigned to the device access
point (slot 0).
Slot 0 Subslot 1
Alarms
Data records (4.5)
Device Access Point (DAP)
Interface connection
C-PLUG
Redundant power supply
Slot 1 to
slot 12
Subslot 8001 - 8002
Alarms (IEC)
Data records (IEC)
Switch port 1.1 - 12.2
Alarm response
Port state