Configuration using Web Based Management and Command Line Interface
4.2 The System menu
SCALANCE X-300 / X-400
44 Configuration Manual, 10/2014, C79000-G8976-C187-22
Note
Note the following points about restarting an IE switch:
You can only restart the IE switch with administrator privileges.
An IE switch should only be restarted with the buttons of this menu or with the
appropriate CLI commands and not by a power cycle on the device.
Any changes you make are only saved on the device after clicking the "Set Value" button
on the relevant page of the WBM, saving the configuration data prior to a restart is neither
necessary nor possible.
The browser must not be set so that it reloads the page from the server each time the
page is accessed. The updating of the dynamic content of the page is ensured by other
mechanisms. In the Internet Explorer, you can make the appropriate setting in the
Options > Internet Options > General
menu in the section
Temporary Internet Files
with
the Settings button.
Below the text
Checkfor newer versions of stored pages
, the
Automatically
check box
must be selected.
Restart System
Click this button to restart the IE Switch. You must confirm the restart in a dialog box. During
a restart, the IE switch is reinitialized, the internal firmware is reloaded, and the device runs a
self-test. The learned entries in the address table are deleted. You can leave the browser
window open while the IE switch restarts.
Restore Memory Defaults and Restart
Click on this button to restore the factory configuration settings with the exception of the
following parameters:
IP addresses (in-band and out-band)
Subnet masks (in-band and out-band)
IP address of the default gateway
DHCP/BOOTP flag
System name
System location
System contact
Ring redundancy
Standby functionality
(R)STP
PNIO device name (name of station)
An automatic restart is triggered.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals