EasyManuals Logo

Siemens SCALANCE X-400 Configuration Manual

Siemens SCALANCE X-400
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Configuration using Web Based Management and Command Line Interface
4.2 The System menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
53
"Login Mode" list box
The login mode provides the following options:
Local:
The login is only possible with the users that exist in the firmware (u
s-
er and admin).
RADIUS and Local:
The login is possible both with the users that exist in the firmware
(use
r and admin) and via a RADIUS server.
The local user names have priority.
RADIUS:
The login is only possible using the login data stored on a RADIUS
server. The local user names are disabled.
Save
Save your entries by clicking the "Set Values" button.
Note
RADIUS authentication fails
If the RADIUS server configured as the primary server fails, authentication will initially fail.
The request is only sent to the backup server with the next login attempt.
Syntax of the Command Line Interface
Table 4- 9 System Passwords - CLI\SYSTEM>
Command
Description
Comment
passwd <admin|user>
Sets a new password for "admin" or "user".
Administrator only.
loginmod [L|B|R] Specifies the login mode:
• L
Only user names that exist in the firmware.
• B
Both the user names in the firmware and
those stored on a RADIUS server (local
names have priority).
• R
Only user names that are stored on a
RADIUS server.
Administrator only.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals