Configuration using Web Based Management and Command Line Interface
4.3 The X-300/X-400 menu
SCALANCE X-300 / X-400
66 Configuration Manual, 10/2014, C79000-G8976-C187-22
Admin Role
The "Admin Role" column shows which mode you have configured for the device:
No Ring Redundancy (off)
The IE switch works without redundancy functionality.
HRP Client (HRP-Clt)
The IE switch operates as an HRP client.
HRP Manager (HRP-Mgr)
The IE switch operates as an HRP manager.
MRP Client (MRP-Clt)
The IE switch operates as an MRP client.
MRP Manager (MRP-Mgr)
The IE switch operates as an MRP manager.
Oper Role
The "Oper Role" column shows the mode adopted by the device in the ring:
No Ring Redundancy (off)
The IE switch works without redundancy functionality.
HRP Client (HRP-Clt)
The IE switch operates as an HRP client.
HRP Manager (HRP-Mgr)
The IE switch operates as an HRP manager.
MRP Client (MRP-Clt)
The IE switch operates as an MRP client.
MRP Manager (MRP-Mgr)
The IE switch operates as an MRP manager.
RM Status
The "RM Status" column shows whether or not the IE switch is operating as redundancy
manager and whether it has opened or closed the ring in this role.
Passive:
The IE switch is operating as redundancy manager and has opened the ring; in other
words, the line of switches connected to the ring ports is operating problem free. The
passive status is also displayed if the IE switch is not operating as the redundancy
manager (RM function disabled).
Active:
The IE switch is operating as redundancy manager and has closed the ring; in other
words, the line of switches connected to the ring ports is interrupted (problem). The
redundancy manager connects its ring ports through and restores an uninterrupted
linear topology.
If media redundancy in ring topologies is completely disabled, no ring ports are
displayed and the text "Ring Redundancy disabled" is displayed.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals