Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
95
Figure 4-27 Agent SNMP Configuration
SNMPv1/v2/v3
Here, you enable / disable SNMPv1, SNMPv2 and SNMPv3 for an IE switch.
SNMPv3 only
If you select this option, you enable SNMPv3 only; the functionality of SNMPv1 and SNMPv2
is not available.
Read Only
When this option is selected, you can only read SNMP variables with SNMPv1/v2c.
Read Community String
Here, you enter the read community string (maximum of 20 characters) for the SNMP
protocol.
Read/Write Community String
Here, you enter the write community string (maximum of 20 characters) for the SNMP
protocol.
Traps
This enables / disables the sending of SNMPv1/v2c traps.