Appendix
A.1 Measured variables
SENTRON PAC4200
Manual, 09/2008, A5E02316180B-01
173
Name Abbrev.
DE + IEC
Abbrev.
EN + NAFTA
Unit Dis-
play
LIM
SOURCE
Minimum reactive power b (VARn) Q
n L2 min
VAR
n b min
VAR 6.2
Minimum value of the reactive power of the harmonics in phase conductor b referred to the load
counting system, measured according to VARn
Reactive power c (VARn) Q
n L3
VAR
n c
VAR 6.0 VARn c
Reactive power of the harmonics in phase conductor c referred to the load counting system,
measured according to VARn
Maximum reactive power c (VARn) Q
n L3 max
VAR
n c max
VAR 6.1
Maximum value of the reactive power of the harmonics in phase conductor c, measured according to
VARn
Minimum reactive power c (VARn) Q
n L3 min
VAR
n c min
VAR 6.2
Minimum value of the reactive power of the harmonics in phase conductor c referred to the load
counting system, measured according to VARn
Reactive Power a (VAR1) Q
1 L1
VAR
1 a
VAR 6.0 VAR1 a
Reactive power of the fundamental in phase conductor a referred to the load counting system,
measured according to VAR1
Maximum reactive power a (VAR1) Q
1 L1 max
VAR
1 a max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Minimum reactive power a (VAR1) Q
1 L1 min
VAR
1 a min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Reactive power b (VAR1) Q
1 L2
VAR
1 b
VAR 6.0 VAR1 b
Reactive power of the fundamental in phase conductor b referred to the load counting system,
measured according to VAR1
Maximum reactive power b (VAR1) Q
1 L2 max
VAR
1 b max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Minimum reactive power b (VAR1) Q
1 L2 min
VAR
1 b min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Reactive power c (VAR1) Q
1 L3
VAR
1 c
VAR 6.0 VAR1 c
Reactive power of the fundamental in phase conductor c referred to the load counting system,
measured according to VAR1
Maximum reactive power c (VAR1) Q
1 L3 max
VAR
1 c max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Minimum reactive power c (VAR1) Q
1 L3 min
VAR
1 c min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Total Apparent Power S VA VA 7.0 ΣVA
Total apparent power in the phase conductors
Maximum total apparent power S
max
VA
max
VA 7.1
Maximum value of the total apparent power in the three-phase system
Minimum total apparent power S
min
VA
min
VA 7.2
Minimum value of the total apparent power in the three-phase system