Backing up and restoring data
Mobile Panel 277 RO
122 Operating Instructions, 10/2015, A5E36824256-AA
Proceed as follows:
1. Start ProSave from the Windows Start menu on the PC.
2. Select the HMI device type "Mobile Panel 277 RO" in the "General" tab.
3. Select "Ethernet" as the connection type between the HMI device and the PC.
4. Enter the IP address or the name of the HMI device.
5. Select the "*.psb" backup file to be restored from the "Restore" tab.
You can see the HMI device for which the backup file was created and the type of backup
data the file contains.
6. Set "Transfer" mode on the HMI device.
If automatic transfer mode is enabled on the HMI device, the device automatically sets
"Transfer" mode when a restore operation is initiated.
7. Start the restore operation in ProSave on the PC with "Start Restore".
If there are license keys on both the HMI device and in the backup, you are asked
whether you wish to overwrite the license keys or to cancel the restore operation.
– If necessary, abort the backup and first back up the HMI device's license keys.
– Then restart the restore process.
Follow the instructions in ProSave.
A status view opens to indicate the progress of the operation.
You have successfully transferred the backed up data from the PC to the HMI device.
Configuring the data channel (Page 96)
Setting the device name of the HMI device (Page 99)
Changing the network configuration (Page 100)