Transport and storage conditions
Mechanical and climatic transport and storage conditions
The transport and storage conditions of this HMI device exceed requirements in accordance
with IEC 61131-2. The following specifications apply to the transport and storage of an HMI
device in its original packaging.
The climatic conditions comply with the following standards:
IEC 60721-3-3, Class 3K7 for storage
IEC 60721-3-2, Class 2K4 for transport
The mechanical conditions are compliant with IEC 60721-3-2, Class 2M2.
The following table shows the transportation and storage conditions for the HMI device.
Type of condition
Permitted range
Drop test (in transport package)
≤ 1 m
Temperature From –20 to +60 °C
Atmospheric pressure From 1080 hPa to 660 hPa,
corresponds to an elevation 1000 to 3,500 m
Relative humidity
From 10 % to 90 %, without condensation
Sinusoidal vibration in accordance with
IEC 60068-2-6
5 Hz to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
Shock in accordance with IEC 60068-2-29
250 m/s
2
, 6 ms, 1000 shocks
The following table shows the transportation and storage conditions for the terminal device.
Type of condition
Permitted range
Drop test (in transport package)
≤ 1 m
Temperature
From –20 to +70 °C
Atmospheric pressure From 1080 hPa to 660 hPa,
corresponds to an elevation 1000 to 3,500 m
Relative humidity
From 35 % to 85 %, without condensation
Sinusoidal vibration in accordance with
IEC 60068-2-6
5 Hz to 8.4 Hz: 3.5 mm
8.4 to 500 Hz: 9.8 m/s
2
Shock in accordance with IEC 60068-2-29
250 m/s
2
, 6 ms, 1000 shocks