EasyManua.ls Logo

Siemens SIMATIC HMI Mobile Panel 277 RO - Safety Characteristics

Siemens SIMATIC HMI Mobile Panel 277 RO
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
10.2 Specifications
Mobile Panel 277 RO
Operating Instructions, 10/2015, A5E36824256-AA
133
10.2.3
Safety characteristics
Note
The fail
-safe performance characteristics in the technical data apply to a proof-test interval
of
20 years.
STOP button
Rated voltage
24 V DC
Minimum current
10 mA, per contact
Max. current carrying capacity
500 mA, per contact
Utilization category
DC-13, in accordance with IEC 60947-5-1
B
10d
100 000
Enabling button
Output type
Solid-state output
Rated voltage, switchable
24 V DC, tolerance 19.2 to 30 V DC in accordance with EN 611312
Rated current, switchable, max.
400 mA
Breaking current, max.
Circuit 1
1.5 A
Circuit 2
0.8 A
Inductive load, max. Circuit 1 145 mJ/1.16 H at 24 V DC, 500 mA
(comparable to 13 DC in accordance
with EN 60947-5-1)
Circuit 2 145 mJ/1.16 H at 24 V DC, 500 mA
(comparable to 13 DC in accordance
with EN 60947-5-1)
Reverse polarity protection
Circuit 1
Yes
Circuit 2
Yes
Short-circuit and overload pro-
tection
Circuit 1
Yes, integrated in the output FET
Circuit 2
Yes, through protective circuit
Switching cycles
Switch position 2
10
5
Switch position 3
5 * 10
4
Actuation forces From switch position 1 to 2,
typical
5 N
From switch position 2 to 3,
typical
20 N
Specifications in accordance with EN ISO 13849-1
Stop with PLUS connection box
Category 3
1.01 * 10
–7
PFH
d
for both channels
1.01 * 10
–7
Enable
Category 3
PL d
PFH
d
1.35 * 10
–7
Panic
Category 3
PL d
PFH
d
1.14 * 10
–7

Table of Contents