Using RemoteOperate Client
7.4 Start client
Mobile Panel 277 RO
Operating Instructions, 10/2015, A5E36824256-AA
115
The RemoteOperate Client can be optionally started with the following parameters:
Server IP address or index (start-
ing with 0) of the server selection dialog (SIMATIC
IPC only)
roClient.exe \ip=192.168.56.2
RemoteOperate Server IP address
roClient.exe \timeout=600
Timeout in seconds: The connection is closed after
a specified perio
d if this client does not carry out
any operation (SIMATIC IPC only).
Special debug tasks for performance measur
e-
ment: This setting is for testing purposes only and
may not be activated during operation (SIMATIC
IPC).
Closing the RemoteOperate Client
Procedure
Proceed as follows:
If you are still connected to a server, close the connection as follows:
1. Press the touch screen until the RemoteOperate toolbar is displayed:
Alternatively, you can click once on the traffic lights.
Note
Setting the time to display the toolbar
The length of time you need to press the touch screen before the RemoteOperate
toolbar
is displayed is defined in the "roServer.ini" file.