Technical specifications
10.3 Mobile Panel 277 RO interface assignment
Mobile Panel 277 RO
136 Operating Instructions, 10/2015, A5E36824256-AA
10.3.3
RJ45 for connecting cable PN
RJ45 plug connector, 8-pin
Pin
Assignment
1
TD+
2
TD
3
RD+
4
n. c.
5
n. c.
6
RD
7
ICD+
8
ICD
10.3.4
Post connector for connecting cable PN
Post connector, 12-pin
Pin
Assignment
Circuit
1
+24 VDC
Power supply
2
GND 24 V
3
Stop 23
STOP circuit
4
Stop 24
5
Stop 13
6
Stop 14
7
Enable 1+
Enable circuit
8
Enable 1
9
Enable 2+
10
Enable 2
11
ICD+
Box ID
12
ICD