Operator controls and displays
5.1 Operator controls and displays on the Mobile Panel 277 RO
Mobile Panel 277 RO
Operating Instructions, 10/2015, A5E36824256-AA
63
Possible application areas for the STOP button:
● The STOP button can be used to initiate a process-cycle-specific rapid stop of a
monitored system (plant, machine or machine zone). The Stop operation can occur with
or without a power shutdown.
Advantages:
– Limitation of effective range
– Fast restart
– No loss of machine coordinates and thus no recalibration upon restart
– Preservation of tool and workpiece
● Triggering of the Emergency Stop function of a monitored system by means of looping in
the Emergency Stop circuit.
Advantage:
Simple integration in an existing Emergency Stop circuit when the system to be
monitored has no option for a fast process stop.
Due to its position, the STOP button is equally accessible to both left-handed and right-
handed individuals.
Due to its profiled design, the STOP button is easily accessible. The STOP button can be
activated if the HMI device is dropped.