Configuring the operating system
6.7 Communication settings
Mobile Panel 277 RO
Operating Instructions, 10/2015, A5E36824256-AA
97
Proceed as follows:
1. You can enable the required data channel by activating the corresponding "Enable
Channel" check box in the "Channel 1" or "Channel 2" group.
In the "Channel 1" group, the RS-422/RS-485 port is enabled for the serial data transfer.
– Activate the "Enable Channel" check box to enable the data channel.
– Deactivate the "Enable Channel" check box to disable the data channel.
2. You can enable automatic transfer by activating the corresponding "Remote Control"
check box in the "Channel 1" or "Channel 2" group.
3. Select the required protocol for "Channel 2" in the selection box.
4. Enter further parameters if required.
– Applies to "MPI/PROFIBUS DP"
Press the "Advanced" button to switch to the "S7-Transfer Settings" dialog box. You
can change the settings for MPI/PROFIBUS DP there.
Confirm your entries.
The "S7-Transfer Settings" dialog box closes.
– Applies to "ETHERNET":
Press the "Advanced" button to switch to the "Network&Dial-Up Connections" dialog
box.
Open the "LAN9001" entry. You can change the TCP/IP settings there.
Confirm your entries.
Close the "Network&Dial-Up Connections" dialog.
– Applies to "USB"
No further settings are required for "USB".
5. Confirm your entries.
The dialog closes.
The data channel is configured.