EasyManuals Logo

Siemens SIMATIC NET SCALANCE W700 User Manual

Siemens SIMATIC NET SCALANCE W700
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
136 Configuration Manual, 08/2018, C79000-G8976-C267-13
6.4.8
Ethernet Statistics
6.4.8.1
Interface Statistics
Interface statistics
The page shows the statistics from the interface table of the Management Information Base
(MIB).
Displayed values
The table has the following columns:
In Octet
Shows the number of received bytes.
Out Octet
Shows the number of sent bytes.
In Unicast
Shows the number of received unicast frames.
In Non Unicast
Shows the number of received frames that are not of the type unicast.
Out Unicast
Shows the number of sent unicast frames.
Out Non Unicast
Shows the number of sent frames that are not of the type unicast.
In Errors
Shows the number of all possible RX errors, refer to the "Packet Error" tab.