EasyManuals Logo
Home>Siemens>Wireless Access Point>SIMATIC NET SCALANCE W700

Siemens SIMATIC NET SCALANCE W700 User Manual

Siemens SIMATIC NET SCALANCE W700
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
147
Description of the displayed values
This table contains the following columns:
Role
Shows the name of the role.
Function Right
Shows the function right of the role:
1
Users with this role can read device parameters but cannot change them.
15
Users with this role can both read and change device parameters.
0
This is a role that the device assigns internally when a user could not be
authenticated. The user is denied access to the device.
Description
Shows a description of the role.
6.4.13.4
Groups
Note
The values displayed depend on the role of the logged
-on user.
This page shows which group is linked to which role. The group is defined on a RADIUS
server. The roll is defined locally on the device.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals