Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
195
6.5.7
Commit Control
Change management
On this page, you specify when the WLAN settings become effective on the SCALANCE W
device.
If you change a WLAN setting and confirm the change with "Set Values", this change is
adopted and takes effect immediately. To do this, the WLAN connection is briefly interrupted.
This means that you can lose the WLAN connection to your SCALANCE W device before it
is fully configured.
With the "Manual Commit" setting, you have the opportunity of first fully configuring the
SCALANCE W device. The changes are accepted, but are not active immediately. The
changes only take effect when you confirm the changes with the "Commit Changes" button.
Note
If you
configure the SCALANCE W device via the WLAN interface, we recommend that you
use the "Manual Commit" setting. Check the parameters again before you confirm the
changes with the "Commit Changes" button.
Description
The page contains the following boxes:
Commit Mode
Select the required setting from the drop-down list.
Automatic Commit
Each change in the WLAN settings is adopted and is immediately effective when you
click the "Set Values" button. In the default setting, the SCALANCE W device is set to
"Automatic Commit".
Manual Commit
The changes are accepted, but are not effective immediately. The changes only take
effect when you click the "Commit Changes" button. The "Commit Changes" button is
displayed when you set "Manual Commit". In addition to this the message "Manual
Commit Mode active - Press 'Commit Changes' button to provide current configuration
to driver." appears as soon as there are WLAN changes. This message can be seen

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals