Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
188 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
The page contains the following:
Interface
Shows the VLAN interface on which IPv6 will be enabled.
IPv6 Enable
Enable or disable IPv6 on the interface. When you enable the setting and accept it, the
link local address is created automatically.
IPv6 Address
Enter the IPv6 address. The entry depends on the selected address type.
Prefix Length
Enter the number of left-hand bits belonging to the prefix
IPv6 Address Type
Select the address type:
Unicast
Link Local: IPv6 address is only valid on the link.
Address Configuration
Specify the mechanism for the address configuration:
Automatic (default)
The IPv6 address is created using a stateless mechanism or a stateful mechanism.
DHCPv6
Status dependent: Obtains the IPv6 address and the configuration file from the
DHCPv6 server.
SLAAC (Stateless Address Auto Configuration)
Stateless autoconfiguration using NDP (Neighbor Discovery Protocol)
Static
Enter a static IPv6 address.
DHCPv6 Rapid Commit
When enabled the procedure for the IPv6 address assignment is shortened. Instead of 4
DHCPv6 messages (SOLICIT, ADVERTISE , REQUEST, REPLY) only 2 DHCPv6
messages (SOLICIT, REPLY) are used. You will find further information on the messages
in RFC 3315.
The table has the following columns:
Select
Select the check box in the row to be deleted.
Interface Name
Shows the name of the VLAN interface.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals