Page #210 background imageLoading...
Page #210 background image
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
210 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
The table has the following columns:
Type
Shows the certificate.
Description
Shows a short description of the certificate.
Enabled
Specifies whether the certificate needs a password. If you enable the setting, specify the
password in "Password".
Password
Enter the password for the certificate.
Note
When assigning the password, you can
only use the following readable ASCII characters:
0x20
- 0x7e.
Password Confirmation
Confirm the password.
State
Shows whether the current settings for the file match the device.
Valid
the "Enabled" check box is selected and the password matches the certificate.
Invalid
the "Enabled" check box is selected but the password does not match the certificate or
no certificate has been loaded yet.
'-'
The password cannot be evaluated or is not yet being used. The "Enabled" check box
is not selected.
Procedure
Assigning the password
1. Enter the password in "Password".
2. To confirm the password, enter the password again in "Password Confirmation".
3. Select the "Enabled" option.
4. Click the "Set Values" button.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals