6.7 "Layer 2" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
332 Configuration Manual, 08/2018, C79000-G8976-C267-13
Table 2 has the following columns:
Port
Shows the available ports and interfaces.
Priority
From the drop-down list, select the priority given to untagged frames.
The CoS priority (Class of Service) used in the VLAN tag. If a frame is received without a
tag, it will be assigned this priority. This priority specifies how the frame is further
processed compared with other frames.
There are a total of eight priorities with values 0 to 7, where 7 represents the highest
priority (IEEE 802.1p Port Priority).
Port VID
Select the VLAN ID from the drop-down list. Only VLAN IDs defined on the "VLAN >
General" page can be selected.
If a received frame does not have a VLAN tag, it has a tag with the VLAN ID specified
here added to it and is sent according to the rules at the port.
Acceptable Frames
Specify which types of frames will be accepted. The following alternatives are possible:
Tagged Frames Only
The device discards all untagged frames. Otherwise, the forwarding rules apply
according to the configuration.
All
The device forwards all frames.
No Change
If "No Change" is selected, the entries of the corresponding column in table 2 remain
unchanged.
Ingress Filtering
Specify whether the VID of received frames is evaluated.
You have the following options:
Enabled
The VLAN ID of received frames decides whether they are forwarded: To forward a
VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames
from unknown VLANs are discarded at the receiving port.
Disabled
All frames are forwarded.
No Change
If "No Change" is selected, the entries of the corresponding column in table 2 remain
unchanged.
Procedure
1. In the row of the port to be configured, click on the relevant cell in the table to configure it.
2. Enter the values to be set in the input boxes as follows.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals