EasyManuals Logo
Home>Siemens>Wireless Access Point>SIMATIC NET SCALANCE W700

Siemens SIMATIC NET SCALANCE W700 User Manual

Siemens SIMATIC NET SCALANCE W700
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #350 background imageLoading...
Page #350 background image
Configuring with Web Based Management
6.8 "Layer 3 (IPv4)" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
350 Configuration Manual, 08/2018, C79000-G8976-C267-13
Description
The page contains the following boxes:
Interface
Select the required Ethernet interface from the drop-down list.
Enable NAT
Enable or disable NAT for the Ethernet interface.
TCP Idle Timeout [s]
Enter the required time in seconds. If no data exchange takes place, the TCP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 2147483.
Default setting: 86400 seconds
UDP Idle Timeout [s]
Enter the required time in seconds. If no data exchange takes place, the UDP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 2147483.
Default setting: 300 seconds
Local Interface IP address
Enter the local IP address of the Ethernet interface. This IP address is the gateway
address of the local device.
Local Interface Subnet Mask
Enter the subnet mask for the local Ethernet.
IPv6 Transparent Mode
When enabled, IPv6 frames are forwarded unchanged between Ethernet and WLAN.
This requires that "Own" is not set for MAC mode and IPv6 is turned off.
If you have set "Manual" for the MAC mode, you need to enter the MAC address of the
IPv6 device that receives or sends the IPv6 frames.
IPv4 Multicast Forwarding
Specify whether or not the incoming multicast frames will be forwarded.
From Global to Local Interface
The multicast frames incoming on the WLAN interface are forwarded via the Ethernet
interface into the internal network.
From Local to Global Interface
The multicast frames incoming on the local Ethernet interface are forwarded via the
WLAN interface into the external network.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals