Icons, buttons, and information displayed in the trend chart
Icon Description
Open padlock
You can change the value.
The value represents a limit for the values that are displayed on the relevant axis.
Closed padlock
You cannot change the value.
The value represents a limit for the values that are displayed on the relevant axis.
Legend Each trend is identified by means of its name and a symbol with the same color as the line. The legend
displays the following information consecutively for the trends shown in the chart
(format: Symbol Name Date:Time: Value):
Trend symbol
Trend name
Date:Time (format: DD:MM:YYYY hh:mm:ss.sss
Value
Value currently being read in (measuring lines not activated)
Cursor points to a measuring line (active measuring line): Value at the intersection of the trend and
measuring line (the values at the intersection point are underlined)
Measuring line Measuring lines
SIMATIC PDM makes a measuring line available in trend charts. The measuring line symbol identifies the
current position of the measuring line.
Legend for measuring line
The value at the intersection of the trend and measuring line is shown at the intersection
Active values are underlined
Interpolated values are not underlined
Using the measuring line
Pull the measuring line to the required position
Removes a measuring line (park position).
Remove measuring line (Alt-Click)
Duplicate measuring line (Ctrl-Click)
White Active
Orang
e
Passiv
e
Shaded trend Cause: Data reduction
The trend includes a large number of data points within the displayed range. The individual values cannot
be displayed.
Dotted trends There are no measured values in a range.
7.9.6 Work with trends
Interaction
The following functions are available in dialog boxes with trends:
Functions
7.9 Graphical displays
Help for SIMATIC PDM (V8.2)