EasyManua.ls Logo

Siemens SINAMICS G120D - Page 238

Siemens SINAMICS G120D
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting functions
8.9 Safe Torque Off (STO) safety function
Converter with control units CU250D-2
238 Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
The STO safety function is standardized
The STO function is defined in IEC/EN 61800-5-2:
"[…] [The inverter] does not supply any energy to the motor which can generate a torque (or
for a linear motor, a force)."
The STO inverter function complies with what is defined in the standard.
The distinction between Emergency Off and Emergency Stop
"Emergency Off" and "Emergency Stop" are commands that minimize different risks in the
machine or plant.
The STO function is suitable for achieving an emergency stop but not an emergency off.
Risk: Risk of electric shock:
Risk of unexpected motion:
Measure to minimize
risk:
Safe switch off
Switching off the electric power
supply for the installation, either
completely or partially.
Safely stop and safely prevent
restarting
Stopping or preventing the dangerous
movement
Command:
Emergency Off
Emergency Stop
Classic solution: Switch of the power supply:
Switch-of the drive power supply:
Solution with the STO
safety function
integrated in the
drive:
STO is not suitable for safely
switching of an electric voltage.
Select STO:
It is permissible that you switch of the
inverter supply voltage as well.
However, switching off the voltage is
not required as a risk-reduction
measurement.

Table of Contents