Commissioning
5.3 Procedure for commissioning via STARTER
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
145
Figure 5-26 Entering the encoder data (option K50)
32. In the Name field, enter a name of your choice.
33. Click the Select standard encoder from list radio button and select one of the available
encoders.
Standard encoders with code numbers 1xxx can be selected when encoder module
SMC10 is fitted (option K46).
Standard encoders with code numbers 2xxx can be selected when encoder module
SMC20 is fitted (option K48).
Standard encoders with code numbers 3xxx can be selected when encoder module
SMC30 is fitted (option K50).