Maintenance and servicing
11.3 Maintenance
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
427
11.3 Maintenance
Servicing involves activities and procedures for maintaining and restoring the operating
condition of the device.
Required tools
The following tools are required for replacing components:
Spanner or socket spanner (w/f 10)
Spanner or socket spanner (w/f 13)
Spanner or socket spanner (w/f 16/17)
Spanner or socket spanner (w/f 18/19)
Hexagon-socket spanner (size 8)
Torque wrench up to 50 Nm
Screwdriver size 1 / 2
Screwdriver Torx T20
Screwdriver Torx T30
Tightening torques for current-carrying parts
When securing connections for current-carrying parts (DC link, motor connections, busbars),
you must observe the following tightening torques.
Table 11-1 Tightening torques for connecting current-carrying parts
Screw Torque
M6 6 Nm
M8 13 Nm
M10 25 Nm
M12 50 Nm