Operation
6.8 PROFINET IO
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
255
Note
Drive objects without PZD do not transfer process data and are used, for example, to
transfer parameters.
6.8.4.4 PROFINET IO with IRT - Overview
Overview
PROFINET IO with IRT is characterized by separate time domains for IRT, RT, and TCP/IP
communication. This is safeguarded by high-precision hardware-based cycle monitoring.
,57
FRPSRQHQW
,57
FRPSRQHQW
,57
FRPSRQHQW
7&3,3
FRPSRQHQW
7&3,3
FRPSRQHQW
7&3,3
FRPSRQHQW
6HQGFORFNLQWHUYDO 6HQGFORFNLQWHUYDO 6HQGFORFNLQWHUYDO
HJPVSRVLWLRQFRQWUROOHUF\FOH
,VRFKURQRXV
FRPPXQLFDWLRQ
7&3,3
FRPPXQLFDWLRQ
,2GDWD 7&3,3GDWD
Figure 6-45 IRT Communication - Overview
PROFINET IO with IRT is available in two versions:
● IRTflex (flexible) with fixed bandwidth reservation
● IRTtop (top performance) with planned IRT communication