EasyManua.ls Logo

Siemens SINAMICS S150 - Direction of Rotation Changeover

Siemens SINAMICS S150
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setpoint channel and closed-loop control
7.2 Setpoint channel
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
261
7.2.2 Direction of rotation changeover
Description
Due to the direction reversal in the setpoint channel the drive can be operated in both
directions.
Use the p110 or p111 parameter to block negative or positive direction of rotation.
Note
If an incorrect rotating field was connected when the cables were installed, and the rotating
field cannot be corrected by swapping the motor cables, it can be corrected when
commissioning the drive via p1821 (rotating field direction reversal) by changing the rotating
field and thus enabling a direction reversal (see section "Direction reversal").
Prerequisites
Direction of rotation changeover is triggered:
via PROFIBUS by means of control word 1, bit 11
via the cabinet operator panel (LOCAL mode) with the "direction of rotation changeover"
key.
Note
Note that only one direction of rotation is enabled in the factory setting when control is
carried out via the AOP30.
Function diagram
FP 3040 Direction of rotation limiting and direction of rotation changeover
Parameters
p1110
Inhibit negative direction
p1111
Inhibit positive direction
p1113
Direction reversal

Table of Contents

Other manuals for Siemens SINAMICS S150

Related product manuals