Operation
6.3 Basic information about the drive system
Drive converter cabinet units
186 Operating Instructions, 07/07, A5E00288214A
Binector-connector converters and connector-binector converters
Binector-connector converter
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
p2080[0...15] BI: PROFIdrive PZD send bit-serial
Connector-binector converter
A 32-bit integer double word or a 16-bit integer word is converted to individual digital
signals.
p2099[0...1] CI PROFIdrive PZD selection receive bit-serial
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n]
CO: Fixed value_%_1
p2901[0...n]
CO: Fixed value_%_2
p2930[0...n]
CO: Fixed Value_M_1
Example:
These parameters can be used to interconnect the scaling factor for the main setpoint or to
interconnect an additional torque.