EasyManua.ls Logo

Siemens SINAMICS S150 - Page 216

Siemens SINAMICS S150
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6.6 PROFIBUS
Drive converter cabinet units
216 Operating Instructions, 07/07, A5E00288214A
Actual torque value (M_Act, M_Act_SMOOTH)
Actual torque value with 16-bit resolution incl. sign bit.
Bit 15 determines the actual value sign:
Bit = 0 -> positive actual value
Bit = 1 -> negative actual value
The actual torque value is normalized via parameter p2003.
M_act = 4000 hex or 16384 dec = torque in p2003
Actual power value (P_Act, P_Act_SMOOTH)
Actual power value with 16-bit resolution incl. sign bit.
Bit 15 determines the actual value sign:
Bit = 0 -> positive actual value
Bit = 1 -> negative actual value
The actual power value is normalized via parameter p2004.
P_act = 4000 hex or 16384 dec = power in p2004
Alarm code (WARN_CODE)
The number of the current alarm and the last alarm to occur are output here. Decimal
notation is used (i.e. value 7910 dec = A07910 (motor overtemperature)).
Fault code (FAULT_CODE)
The number of the oldest fault still active is output here. Decimal notation is used (i.e. value
7860 dec = F07860 (external fault 1)).