EasyManua.ls Logo

Siemens SINAMICS S150 - Page 385

Siemens SINAMICS S150
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions, monitoring, and protective functions
9.4 Extended functions
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
385
Task (p2621[0...63])
1: POSITIONING
3: ENDLESS_POS
4: ENDLESS_NEG
5: WAIT
6: GOTO
7: SET_O
8: RESET_O
Motion parameters
Target position or traversing distance (p2617[0...63])
Velocity (p2618[0...63])
Acceleration override (p2619[0...63])
Deceleration override (p2620[0...63])
Task mode (p2623[0...63])
Processing a traversing block can be influenced by means of parameter p2623 (task
mode). This is described automatically by programming the traversing blocks in
STARTER.
Value = 0000 cccc bbbb aaaa
aaaa: Display / hide
0000: Block is not hidden
0001: Block is hidden
A hidden block cannot be selected binary-coded via
binector inputs p2625 to p2630. An alarm is output if
you attempt to do so.
bbbb: Continuation condition
0000, END: 0/1 edge at p2631
0001, CONTINUE_WITH_STOP: The position parameterized in the block is approached
accurately (brake to standstill and positioning window
monitoring) before block processing is continued.
0010, CONTINUE_ON-THE-FLY: An on-the-fly change is made to the next traversing
block once the brake usage point of the current block
is reached (if a change in direction is required, the
change only takes place during a stop in the
positioning window)