Functions, monitoring, and protective functions 
  9.4 Extended functions 
Drive converter cabinet units 
Operating Instructions, 07/07, A5E00288214A 
385 
●  Task (p2621[0...63]) 
1: POSITIONING 
3: ENDLESS_POS 
4: ENDLESS_NEG 
5: WAIT 
6: GOTO 
7: SET_O 
8: RESET_O 
●  Motion parameters 
–  Target position or traversing distance (p2617[0...63]) 
–  Velocity (p2618[0...63]) 
–  Acceleration override (p2619[0...63]) 
–  Deceleration override (p2620[0...63]) 
●  Task mode (p2623[0...63]) 
Processing a traversing block can be influenced by means of parameter p2623 (task 
mode). This is described automatically by programming the traversing blocks in 
STARTER. 
Value = 0000 cccc bbbb aaaa 
 
aaaa: Display / hide 
0000:  Block is not hidden 
0001:  Block is hidden 
A hidden block cannot be selected binary-coded via 
binector inputs p2625 to p2630. An alarm is output if 
you attempt to do so. 
bbbb: Continuation condition 
0000, END:  0/1 edge at p2631 
0001, CONTINUE_WITH_STOP:  The position parameterized in the block is approached 
accurately (brake to standstill and positioning window 
monitoring) before block processing is continued. 
0010, CONTINUE_ON-THE-FLY:  An on-the-fly change is made to the next traversing 
block once the brake usage point of the current block 
is reached (if a change in direction is required, the 
change only takes place during a stop in the 
positioning window)