EasyManua.ls Logo

Siemens SINAMICS S150 - Page 91

Siemens SINAMICS S150
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
4.9 Other connections
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
91
X1400 Ethernet interface
Table 4-38 Connector X1400, port 1 - 4
Pin Signal name Technical specifications
1 RX+ Receive data +
2 RX- Receive data -
3 TX+ Transmit data +
4 --- Reserved, do not use
5 --- Reserved, do not use
6 TX- Transmit data -
7 --- Reserved, do not use
8 --- Reserved, do not use
Screened backshell M_EXT Screen, permanently connected
Assembly
CAUTION
The Option Board should only be inserted and removed when the Control Unit and Option
Board are disconnected from the power supply.
5HOHDVHDQGUHPRYH
WKHSURWHFWLYHFRYHU
)L[LQJVFUHZV
01P
7RU[7
,QWURGXFHDQG
IL[WKH
2SWLRQ%RDUG
Figure 4-14 Mounting the CBE20