MBR Motor holding brake
• 1: motor holding brake is closed
• 0: motor holding brake is released
: MBR is only status signal because the control and the
power supply of the motor holding brake is realized with
separate terminals.
✓ ✓
OLL Overload level reached
• 1: motor has reached the parameterizable output over-
load level (p29080 in % of rated torque, default: 100%,
max: 300%)
• 0: motor has not reached the overload level
✓ ✓
RDY_ON Ready for servo on
• 1: ready to servo on
• 0: drive is not ready for servo on (fault occurs, main
power supply is missing, or STW1.1 and STW1.2 are
not set to 1)
After the drive is servo on, the signal remains in 1
status unless the above abnormal cases happen.
✓ ✓
INP In-position signal
• 1: number of droop pulses is in the preset in-position
range (parameter p2544)
• 0: droop pulses are beyond the in-position range
X ✓
REFOK Referenced
• 1: referenced
• 0: not referenced
X ✓
STO_EP STO active
• 1: the enable signal is missing, indicating that STO is
active.
• 0: the enable signal is available, indicating that STO is
inactive.
STO_EP is only a status signal for STO input termi-
nals but not a safe DO for the Safety Integrated function.
✓ ✓