13
Additional Functions 12.98
13.4 EG: Electronic
ear
SW 5 and hi
her
13
840D
NCU 571
840D
NCU 572
NCU 573
FM-NC 810D 840Di
Siemens AG 2000. All rights reserved
13-442
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
Coupling type1, ... coupling type5
Following axis is influenced by:
0: actual value
1: setpoint
of the respective leading axis
Programming
EGDEF(C, B,1, Z, 1, Y, 1)
B, Z, Y inflluence C via setpoint
The coupling type does not need to be identical for
all leading axes and is therefore specified for each
leading axis individually.
The coupling factors are preset with zero for
definition of the EG coupling group.
Prerequirement for an EG axis grouping definition:
An axis coupling may not yet be defined for the
following axis (if necessary, any existing one must
first be deleted with EGDEL).
Note
EGDEF triggers preprocessing stop.