EasyManua.ls Logo

Siemens SINUMERIK 840D

Siemens SINUMERIK 840D
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
04.00 Tables
15.2 List of s
y
stem variables
15
Siemens AG 2000. All rights reserved
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) 04.00 Edition
15-573
Identifier Type Description: System variable/value range/index Part pro Sync O S
$A_INSIP
BOOL $A_INSIP[n]
Image of a Safety input signal (int. PLC interface)
n: Number of input word 1 ...
RS R 4
$A_INSIPD
INT $A_INSIPD[n]
Image of Safety input signals (int. PLC interface)
n: Number of input word 1 ...
RS R 5
$A_OUTSI
BOOL $A_OUTSI[n]
Image of a Safety output signal (int. NCI interface)
n: Number of output 1 ...
RS W
S
RW 4
$A_OUTSID
INT $A_OUTSID[n]
Image of Safety output signals (int. NCI interface)
n: Number of output word 1 ...
RS W
S
RW 5
$A_OUTSIP
BOOL $A_OUTSIP[n]
Image of a Safety output signal (int. PLC interface)
n: Number of output 1 ...
RS R 4
$A_OUTSIPD
INT $A_OUTSIPD[n]
Image of Safety output signals (int. PLC interface)
n: Number of output word 1 ...
RS R 5
$A_MARKERSI
BOOL $A_MARKERSI[n]
Markers for Safety programming
n: Number of marker 1 ...
RS W
S
RW+ 4
$A_MARKERSID
INT $A_MARKERSID[n]
Marker word (32 bits) for Safety programming
n: Number of marker word 1 ...
RS W
S
RW+ 5
.
1
$A_MARKERSIP
BOOL $A_MARKERSIP[n]
Image of PLC Safety markers
n: Number of marker 1 ...
RS R + 4
$A_MARKERSIP
D
INT $A_MARKERSIPD[n]
Image of PLC Safety marker words
n: Number of the flag word 1 ...
RS R + 5
.
1
$A_TIMERSI
REAL $A_TIMERSI[n]
Safety timer unit in seconds
Time is counted internally in multiples of interpolation cycle
cycle;
Counting for the timer variable is started by assigning the value
$A_TIMERSI[n]=<starting value>
To stop the counter variable, assign a negative value:
$A_TIMERSI[n]=1
The current time can be read while the counter is active or stopped.
When the timer is stopped by assigning the value 1, the most up-to-
date timer value is retained and can be read.
n: Number of timer 1 ...
RS W
S
RW+ 4