SIRIUS 3RU2/3RB3 overload relays   
5.2 Product description 
  SIRIUS Innovations 
488  System Manual, 01/2011, A8E56203870002-03 
5.2.3  Applications 
Table 5- 3  Overview of applications 
Applications  3RU21  3RB30/3RB31 
System protection  ✓
1)
 ✓
1)
 
Motor protection  ✓  ✓ 
Alternating current, 3-phase  ✓  ✓ 
Alternating current, 1-phase  ✓  - 
Direct current  ✓  - 
1)
  In the main circuit, the devices provide overload protection for the assigned electrical loads (e.g. 
motors), feeder cable, and other switching and protection devices in the respective load feeder. 
The 3 phases have to be under symmetrical load. 
3RU21 thermal overload relays 
3RU21 thermal overload relays have been designed to protect three-phase loads, DC loads, 
and single-phase AC loads.  
 
 
Note 
Protection of DC loads/single-phase AC loads 
If a 3RU21 thermal overload relay is to be used to protect DC loads or single-phase AC 
loads, all the bimetal strips have to be heated. Therefore, all of the relay's main current paths 
have to be connected in series. 
 
3RB30/3RB31 solid-state overload relays 
3RB30/3RB31 solid-state overload relays are designed to protect three-phase loads in 
sinusoidal 50/60 Hz voltage supplies.  
 
 
Note 
DC loads/Single-phase AC loads 
The relay is not suitable for protecting DC loads or single-phase AC loads. In the case of 
loads with single-pole load, the 3RU21 thermal overload relay or the 3RB22/3RB23 solid-
state overload relay (only suitable for the protection of single-phase AC loads) should be 
used. 
 
Reference 
 
More information ...  Can be found in the chapter titled ... 
About overload relay applications  Configuration (Page 503)