ID/
Icons
Diagnostic Action Comment
174 Display FW invalid. A component does not have the ex‐
pected FW version. Start a product firmware
update to update the component version or re‐
place the component.
175 IO FW invalid. A component does not have the ex‐
pected FW version. Start a product firmware
update to update the component version or re‐
place the component.
176 Sensor Sensor type incompatible. Please replace sen‐
sor.
177 Device is starting Please wait until startup is finished. Startup time
see manual.
178 Transmitter FW invalid. A component does not have the ex‐
pected FW version. Start a product firmware
update to update the component version.
179 Alarm class Alarm class simulated. Disable Simulation be‐
fore returning to normal operation.
No detailed information availa‐
ble in view Active diagnostic
events. Icon depends on simu‐
lated alarm class resp. NA‐
MUR status signal and the pri‐
ority in case of multiple alarm
classes simulated.
181 SensorFlash SensorFlash Chkdsk failed. Start Chkdsk
again. If error still exists replace SensorFlash.
183 CH2 Input current too low. Check wiring and signal of
connected sensor or output source to input
channel.
If Operation mode is config‐
ured to Current input.
184 CH2 Input current too high. Check wiring and signal
of connected sensor or output source to input
channel.
If Operation mode is config‐
ured to Current input
Diagnostics and troubleshooting