Code Command explanation Comment
131
Display distribution memory 4
Display total weight value in DR 34 (total 4 from DR
33).
132
Display distribution memory 5
Display total weight value in DR 34 (total 5 from DR
33).
133
Display distribution memory 6
Display total weight value in DR 34 (total 6 from DR
33).
134
Display distribution memory 7
Display total weight value in DR 34 (total 7 from DR
33).
135
Display distribution memory 8
Display total weight value in DR 34 (total 8 from DR
33).
136
Display flow rate 1 in DR 34
Display flow rate 1 in DR 34 (from DR 32).
137
Display flow rate 2 in DR 34
Display flow rate 2 in DR 34 (from DR 32).
138
Display flow rate 3 in DR 34
Display flow rate 3 in DR 34 (from DR 32).
139
Show belt loading in DR 34
Display of the belt loading in DR 34 (from DR 31).
140
Show verifiable weight B/N in DR 34
Return to weight display.
142
Display flow rate 1 (%) in DR 34
Display the flow rate (in % of nominal flow rate) in
DR 34 (from DR 32).
143
Display belt loading (%) in DR 34
Display of the belt loading (% of the nominal belt
load) in DR 34 (from DR 31).
144
Display belt speed (%) in DR 34
Display of the belt speed (% of the nominal speed of
the belt) in DR 34 (from DR 31).
Table 6-1 SIWAREX FTC command list
The commands in the table above can be activated over all interfaces.
6-96 SIWAREX FTC