WEIGHING FUNCTIONS AND PARAMETERS
Bit No. Name Range of Values / Meaning Reference
23 Reserved Reserved
24 Reserved Reserved
25 Empty message Scale in empty range
26 Calibration data protection The switch for protecting the calibration data is switched on
27 Reserved Reserved
28 Reserved Reserved
29 Reserved Reserved
30 Standalone operation
activated
1, if standalone operation has been activated
31 Operating error At least one operating error (fault) exists
Table 5-14 DR 30 - NAWI status bits
5.15.2 DR 30 - Conti-Status Flags
Bit No. Name Range of Values / Meaning Reference
0 Belt control status
0: Belt control OFF
1: Belt control ON
1 Totalizing status
1: Recording and totalizing of the dosing quantity is active
0: Dosing quantity will not be recorded
2 Min. belt loading exceeded Belt loading min has been exceeded (is returned with a
delay in cases)
3 Belt loading max. exceeded Belt max has been exceeded (is indicated with a delay in
cases)
4 Min. belt speed exceeded Min. belt speed exceeded (returned with a delay in cases)
5 Max. belt speed exceeded Max. belt speed exceeded (is indicated with a delay in
cases)
6 Min. pulse undercut
1 = Pulse encoder generates less than 2 pulses / second
0 = Pulse encoder generates a minimum of 2 pulses /
second
7 Min. belt load exceeded for
totalizing
1= Min. belt load exceeded for totalizing, the totalizing can
be performed
8 Scale in dynamic zero
setting range
=1, if the scale is in the dynamic zero setting range
9 Dynamic adjustment or zero
setting procedure is running
=1, if dynamic adjustment or zero setting procedure is
running
10 Dyn. zero setting aborted 1: If dynamic zero setting could not be completed or was
ended early because of leaving the zero setting range
11 Volumetric operation Volumetric operation in automatic mode.
12
Filling Filling activated.
13
> max. flow rate +/- Change speed of flow rate too great
14 > min. flow rate Minimum flow rate achieved
15 > max. flow rate Maximum flow rate exceeded (in relation to the nominal
flow rate or setpoint)
16
Pulse 1 external Pulses f. external summator 1
17
Pulse 2 external Pulses f. External summator 2
18
Gravimetric operation Gravimetric mode in automatic operation.
19
Emptying activated The command for emptying was activated. Scale will not
refill, the container will empty until the limit value "Empty
range"from DR 4.
20
Max. control difference Maximum control difference exists.
21
Reserved Reserved
22 Max. filling time The maximum filling time has been achieved.
23 Max. time max. control
difference
The maximum control difference is at the max. defined
monitoring time.
24 Max. vol. time The volumetric mode is active longer than the defined
max. monitoring time.
25 Reserved Reserved
SIWAREX FTC
5-75