WEIGHING FUNCTIONS AND PARAMETERS
Name Type Address Default Range of Values / Meaning Reference
Bits 1 to 7 not used
Reserve_4_9 BYTE DBB009 0 Reserved
Basis weight for limit
value 1
Basis weight for limit
value 2
Basis weight for the
empty range
BYTE DBB010 0
0
Bit 0 :
0 = Basis for limit value 1 is the gross weight
1 = Basis for limit value 1 is the net weight
Bit1 :
0 = Basis for limit value 2 is the gross weight
1 = Basis for limit value 2 is the net weight
Bit 3 :
0 = Basis for the empty range is the gross
weight
1 = Basis for the empty range is the net
weight
Bits 4 to 7 not used
5.4.3
5.4.4
5.4.5
Reserve_4_11 BYTE DBB011 0 Reserved
Empty range
REAL DBD012 1
For filling procedures, this depends on
parameters, for emptying procedures relative
to gross. With the loss-in-weight scale: Limit
value for ending the emptying run.
5.4.6
Switch-on weight
Limit value 1
REAL DBD016 1
Switch-on weight
Limit value 1
5.4.7
Cut-off weight
Limit value 1
REAL DBD020 1,1
Cut-off weight
Limit value 1
5.4.8
Switch-on weight
Limit value 2
REAL DBD024 50
Switch-on weight
Limit value 2
5.4.9
Cut-off weight
Limit value 2
REAL DBD028 49
Cut-off weight
Limit value 2
5.4.10
Switch-on weight
Limit value 3
REAL DBD032 99
Limit value 3 corresponds with overfill limit
5.4.11
Cut-off weight
Limit value 3
REAL DBD036 98
Cut-off weight limit value 3
5.4.12
40
Table 5-3 Allocation of DR 4
5.4.1 DR 4 - Monitoring Time for Logging
If logging of the wei
ghing results is generated by an instruction or automatically,
SIWAREX FTC monitors whether the procedure has been completed within the
predefined time. If not, an error is generated.
5.4.2 DR 4 - Device for the Log Output
Log
s can be output to a connected printer or to the Micro Memory Card (MMC).
The contents of the log are defined in data records DR 40 to DR 43.
5.4.3 DR 4 - Basis Weight for Limit Value 1
The limit values can be d
efined in relation to the gross weight or the net weight of
the scale.
5.4.4 DR 4 - Basis Weight for Limit Value 2
The limit values can be d
efined in relation to the gross weight or the net weight of
the scale.
SIWAREX FTC