Name Type Address Default Range of Values / Meaning Reference
Boot loader version
WORD DBW130 0
Scale type
STRING
[4]
DBB132 „CONT„
or
„NAWI“
Reserved WORD DBW138 0 Reserved
140
Table 5-6 Allocation of DR 9
5.8.1 DR 9 - Info on Module
The inform
ation on the SIWAREX FTC module is for the purpose of identifying the
module in the manufacturer's plant (e.g. for repairs). This information has no
influence on user operation.
5.9 DR 14 Tilt angle
DR 14 is used for an external definition of the tilt angle for the belt scale.
Procedure:
o Enter tilt angle
o Send DR 14 to the scale
Name Type Address Default Range of Values / Meaning Reference
Tare entry
Tilt angle entry
INT DBB000 0 Definition for the belt tilt 0° to 60° (0...600)
5.9.1
2
Table 5-7 Allocation of DR 14
5.9.1 DR 14 – Tilt angle definition for the belt
DR 14 is used for an external definition of the belt tilt angle. If the belt is
mounted horizontally, the definition is 0. The belt can be tilted to a
maximum of 60°.
Always ensure that the definition corresponds with the current tilt angle,
otherwise the belt load will be calculated incorrectly.
5.10 DR 15 Tare Entry
DR 15 is used for external specification of the tare weight.
Procedures:
o Enter tare weight
o Send the DR 15 to the scale
o Activate the command "Accept tare entry (24)"