EasyManua.ls Logo

Siemens SIWAREX FTC - Table 7-1

Siemens SIWAREX FTC
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WEIGHING FUNCTIONS AND PARAMETERS
Name Type Address Default Range of Values / Meaning Reference
Characteristic value
range
BYTE DBB036 2 1: Characteristic value to 1mV/V
2: Characteristic value to 2mV/V
4: Characteristic value to 4mV/V
101: Characteristic value +/- 1mV/V (force
measurement, bi-directional)
102: Characteristic value +/- 2mV/V (force
measurement, bi-directional)
104: Characteristic value +/- 4mV/V (force
measurement, bi-directional)
Other definitions not permitted.
5.2.2
(5) Filter
Filter sequence
BYTE DBB037 0 Bit 0 :
0: Average value filter before digital filter
1: Digital filter before average value filter
Bits 1 to 7 not set
5.2.3
Type of low pass filters
BYTE DBB038 0 0: critically damped
1: Bessel filter
2: Butterworth filter
Other definitions not permitted.
5.2.4
Limit Frequency
BYTE DBB039 4 0: No filter
1: fg = 20Hz
2: fg = 10Hz
3: fg = 5Hz
4: fg = 2Hz
5: fg = 1Hz
6: fg = 0.5Hz
7: fg = 0.2Hz
8: fg = 0.1Hz
9: fg = 0.05Hz
Other definitions not permitted.
5.2.5
Depth of
average value filter
INT DBW040 10 [0 ... 250] x 10 ms
0: Average value filter deactivated
Other definitions not permitted.
5.2.6
(1) Adjustment parameter
I
0
Scale Name
STRING
[10]
DBB042 „SIWAREX
XX“
5.2.7
Number of weight ranges
BYTE DBB056 1 1 Range
2 Ranges
3 Ranges
Other definitions not permitted.
5.2.8
Scale type
Activate zero setting
upon start-up
Activated zero setting at
start-up, if scale is tared
Automatic zero
adjustment
BYTE DBB057 0
0
0
0
Bit 0::
0: Multi-range scale
1: Multi-resolution scale
Bit 1:
0: Switch-on zero setting device switched off;
1: Switch-on zero setting device switched on
Bit 2:
0: Switch-on zero setting, not when tare 0
1: Switch-on zero setting performed with tare 0
Bit 3:
0: Zero tracking device switched off;
1: Zero tracking device switched on
Bit 4 - 7 not set
5.2.9
5.2.10
5.2.11
5.2.12
(2) Calibration parameter
II
Minimum weight for
Weighing range 1
REAL DBD058 1
5.2.13
SIWAREX FTC
5-33

Table of Contents