Name Type Address Default Range of Values / Meaning Reference
Maximum weight for
weighing range 1
REAL DBD062 100
5.2.14
Numeral step for
weighing range 1
REAL DBD066 0,02 Number step weighing range 1 (1*10
k
, 2*10
k
,
5*10
k
, k ∈ N
0)
Other definitions not permitted.
5.2.15
Minimum weight for
Weighing range 2
REAL DBD070 0
5.2.16
Maximum weight for
weighing range 2
REAL DBD074 0
5.2.17
Numeral step for
weighing range 2
REAL DBD078 0
Number step WB2 (1*10
k
, 2*10
k
, 5*10
k
, k ∈ N
0)
Other definitions not permitted.
5.2.18
Minimum weight for
Weighing range 3
REAL DBD082 0
5.2.19
Maximum weight for
weighing range 3
REAL DBD086 0
5.2.20
Numeral step for
weighing range 3
REAL DBD090 0
Numeral step WB3 (1*10
k
, 2*10
k
, 5*10
k
, k ∈ N
0)
Other definitions not permitted.
5.2.21
(3) Calibration parameter
III
Standstill Time
TIME DBD094 1000 ms
5.2.22
Standstill Range
REAL DBD098 0,02 Standstill range in weight unit
5.2.23
Wait time for standstill
TIME DBD102 2000 If there is no standstill, the weighing command
is immediately rejected with an operating error
at setting 0 and otherwise the wait time is
waited through. If no standstill has occurred
after the wait time has elapsed, an error
message is generated and the command is
aborted. For weighing commands (zero setting,
taring in operation as non-automatic weighing
instrument) that are activated by an operator, a
setting in the 2000 ms range is a good idea.
5.2.24
Max. negative weight for
zero setting when
switching on
BYTE DBB106 10 Neg. Range of the switch-on zero setting device
[in % of WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 20% for country code „OIML“)
Deactivated for loss-in-weight scale.
5.2.25
Max. positive weight for
zero setting when
switching on
BYTE DBB107 10 Pos. range for switch-on zero setting device [in
% of WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 20% for country code „OIML“)
Deactivated for loss-in-weight scale.
5.2.26
Maximum negative
weight for zero setting
BYTE DBB108 1 Neg. Range of zero setting device [in % of
WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 4% for country code „OIML“)
5.2.27
Maximum positive weight
for zero setting
BYTE DBB109 3 Neg. Range of zero setting device [in % of
WB
max
]
(Entry from Pos- + Neg. Zero setting value may
not exceed 4% for country code „OIML“)
5.2.28
Tare max. weight T-
BYTE DBB110 100 Subtractive tare device range
[in % of WB
max
with multi-range scale]
[in % of WB
1
with multi-resolution scale]
(Entry may not exceed 100% with country code
"OIML")
5.2.29
5-34 SIWAREX FTC