WEIGHING FUNCTIONS AND PARAMETERS
5.15.12
DR 30 - Nominal Load
From the n
ominal flowrate (defined in DR 5) and nominal speed (defined in DR 5)
calculated nominal belt load in the dimension weight unit/length unit [WU/LU].
5.15.13 DR 30 - Belt Load
The cu
rrent belt load is output as the relationship of the currently measured weight
to the effective belt length. The dimension is: Weight unit/Length unit [WU/LU].
5.15.14 DR 30 – Flowrate 1
The cu
rrent flowrate 1 is output in the dimension Weight unit / sec [WU/s].
5.15.15 DR 30 – Flowrate 2
The cu
rrent flowrate 2 is output in the dimension Weight unit/h [WU/h].
5.15.16 DR 30 – Flowrate 3
The cu
rrent flowrate 3 is output in the dimension Large Weight Unit / h [LWU/h].
5.15.17 DR 30 – Flowrate in % of the Nominal Flowrate
The cu
rrent flowrate is output in % of the nominal flowrate.
5.15.18 DR 30 – Operating Hours Counter
The ope
rating hours counter records the number of hours that the SIWAREX FTC
is supplied with 24V voltage.
5.15.19 DR 30 – Pulse Counter Value
Curre
nt counter value on the pulse input in relation to the defined measurement
time.
5.16 DR 31 Process Status 2 (all operating modes)
The user or the service technician can retrieve information on the current status of
the scale in the expanded process values.
Name Type Address Range of Values / Meaning Reference
Unfiltered digital value
DINT DBD000 Unfiltered digital value from ADU
5.16.1
Filtered digital value
DINT DBD004 Filtered digital value from filter level 1 for
NAWI-Fct.
5.16.2
Reserve33_1
DINT DBD008 Reserved
Operating error
DWORD
DBD012
Error word Operating error (for test dept.,
Bit-No. = Error code –1)
5.16.3
curr. Date/Time
DATE_A
ND_TIME
DBD016 curr. Date/Time
5.16.4
Current temperature
INT DBW024 Current inner-temperature of the module
[0.1°C]. If no temperature value is available: -
100.0°C.
5.16.5
SIWAREX FTC
5-77