WEIGHING FUNCTIONS AND PARAMETERS
Defining
the operating mode is done during the initial commissioning of the
module by sending the adjustment data record DR 3 with the newly defined
operating mode.
Data records or individual parameters, which have no effect in a certain operating
mode, are also taken and stored in the SIWAREX FTC module.
The following operating modes can be defined:
- 0 - non-automatic weighing instrument (OIML R 76) for fill scales
- 0 - non-automatic weighing instrument (OIML R 76) for emptying scales
- 2 - Force measurement (bi-directional)
- 3 – Belt scale (Default value, Description in separate manual)
- 4 - Loss-in-weight scale
- 5 - Bulk flow measurement device
5.2.31 DR 3 - Weighing Operating Mode: NAWI Filling Procedure
Non
-automatic weighing instrument (NAWI) - according to OIML R-76 - only
accepts the service and adjustment instructions and weighing instructions "zero
setting" and "taring". The net weight increases with increasing load on the scale.
5.2.32 DR 3 - Operating Mode: NAWI Emptying Procedure
Non
-automatic weighing instrument (NAWI) - according to OIML R-76 - only
accepts the service and adjustment instructions and weighing instructions "zero
setting" and "taring". The net weight increases with decreasing load on the scale.
5.2.33 DR 3 - Operating Mode: Force Measurement
This op
erating mode is not legal-for-trade. The scope of functionality is similar,
but with operating mode "non-automatic weighing instrument filling procedure".
The difference is in the ability to use the measuring range in the positive and
negative direction.
5.2.34 DR 3 - Operating Mode: Belt Scale
In operatin
g mode Belt scale, the parameters from the DR 5 are also evaluated.
The scope of functionality is designed for operation with a belt scale. The belt scale
is described in a separate manual.
5.2.35 DR 3 - Operating Mode: Loss-in-weight Scale
In operatin
g mode Loss-in-weight scale, the adjustment parameters from data
records DR 6, DR 10, DR 11, DR 12 and DR 13 are also evaluated. The scope of
functionality is designed for operation with a loss-in-weight scale.
5.2.36 DR 3 - Operating Mode: Bulk Flow Measurement Device
In operatin
g mode Bulk flow measurement device, the adjustment parameters from
the DR 55 are also evaluated. The scope of functionality is designed for operation
with a bulk flow measurement device.