5.5.12 DR 5 – Minimum flow-rate
Minimum flow-rate is a limit value for minimum flow-rates in % of the
nominal flow-rate. The entry of the number e.g. 800 corresponds with 80.0
%. After this value has been undercut, SIWAREX FTC sets a status bit.
5.5.13 DR 5 – Maximum flow-rate
Maximum flow-rate is a limit value for maximum flow-rates in % of the
nominal flow-rate. The entry of the number e.g. 1020 corresponds with
102.0 %. After this value has been exceeded, SIWAREX FTC sets a status
bit.
5.5.14 DR 5 – Minimum belt loading
Minimum belt loading is a limit value for minimum belt loading in % of the
nominal belt loading. The entry of the number e.g. 800 corresponds with
80.0 %. After this value has been undercut, SIWAREX FTC sets a status
bit. In batch mode the totalizing will be completed after the dosing signal is
switched off and the belt loadin is less than this limit value.
5.5.15 DR 5 – Maximum belt loading
Maximum belt loading is a limit value for maximum belt loading in % of the
nominal belt loading. The entry of the number e.g. 1020 corresponds with
102.0 %. After this value has been exceeded, SIWAREX FTC sets a status
bit.
5.5.16 DR 5 – Maximum belt loading for zero setting
Maximum belt loading for zero setting is a limit value for maximum belt
loading in % of the nominal belt loading. Entering the number e.g. 20
corresponds with 2.0 %. After this value has been exceeded, SIWAREX
FTC will not execute the zero setting instruction.
5.5.17 DR 5 - Minimum belt loading for totalizing
Minimum belt loading for totalizing is a limit value for minimum belt loading
in % of the nominal belt loading. Entering the number e.g. 20 corresponds
with 2.0 %. After the actual value is less than the limit, SIWAREX FTC will
not execute the totalizing function.
5.5.18 DR 5 – Delay time for the monitoring of the belt loading after the start
After the belt is switched on, undercutting the minimum belt loading or the
minimum flow-rate is only indicated after this time has elapsed.
5.5.19 DR 5 – Delay time for monitoring the belt loading in continuous operation
After the minimum belt load has been undercut or the minimum flow-rate is
undercut, the respective message or status bit is output only after this time
has elapsed.