Index
(with log output
0xFF,nn)
Value S7 Log
field
Field length
[Byte]
(for log field
only)
Field layout (example)
(for log field only)
NAWI fields (nn)
0 NAWI status flags j n - -
1 Grossweight_Process j j 14 •12345.678•kg•
2 Netweight_Process j j 14 •12345.678•kg•
3 Tareweight_Process j j 14 •12345.678•kg•
4 B/N weight verifiable
j j 18 <N1•12345.678•kg•>
<B1•-12345.67•kg•>
5 B/N Weight_x10 j n - -
6 Tare weight (verifiable /
calibratable)
j j 18 <PT•12345.678•kg•>
7 Pulse counter value j j 10 1234567890
8 Temperature j n 5 21.5
9 Operating error j n - -
10
Unfiltered raw value
j n - -
11
Filtered raw value 1
j n - -
12 Log ID n j 16 <No•1234567890•>
13 Date (dd.mm.yy) n j 8 27.12.02
14 Date (yy-mm-dd) n j 8 02-12-27
15 Time n j 8 13:05:00
16 String 1 n j 16 Milk powder •••••
17 String 2 n j 16 Bread crumbs••••
18 String 3 n j 16 Sugar••••••••••
19 String 4 n j 16 Wheat flour••••••
20
21 Description n j 10 <Differential_dosing_scale1>
22
23
24
25
26
27
28
29
Conti-Fields (nn)
30 Conti-Status flags j n -
31 Distribution memory 1 j j 16 S1•12345678.9•kg
32 Distribution memory 2 j j 16 S2•12345.6789•kg
33 Distribution memory 3 j j 16 S3•12345.6789•kg
34 Distribution memory 4 j j 16 S4•12345.6789•kg
35 Distribution memory 5 j j 16 S5•12345.6789•kg
36 Distribution memory 6 j j 16 S6•12345.6789•kg
37 Distribution memory 7 j j 16 S7•12345.6789•kg
38 Distribution memory 8 j j 16 S8•12345.6789•kg
39 Flow rate 1 j j 16 F1•1234567.8kg/s
40 Flow rate 2 j j 16 F2•1234567.8kg/h
41 Flow rate 3 j j 16 F3•1234567.8•t/h
42
Belt speed
j j 16 BS•1234567.8•m/s
43 Belt load j j 16 BB 1234567.8kg/m
44 Flow in % j j 16 FS•123•%••••••••
45 Belt load in % j j 16 BB•123•%••••••••
46 Belt speed in % j j 16 BS•123•%••••••••
47
Current setpoint
j j 18
SP•1234567.8kg/s
48
Effective setpoint
j j 18
SW•1234567.8kg/s
49
Current control difference
j j 18
DI•1234567.8kg/s
50
Act. Control difference in %
j j 10 D•123,00•%
51
Act. Difference vol/grav in % j
j
10
K•123,00•%
5-82 SIWAREX FTC