31/238
Building Technologies Modular Heating Controller RMH760B CE1P3133en
HVAC Products 3 Commissioning 05.02.2007
• “N.“ in the tables denotes “controller“
• If required, additional inputs and outputs (e.g. flue gas temperature sensor, operating
mode relay, circulating pump) can be assigned to the free inputs and outputs via “Ex-
tra configuration”
• The inputs and outputs can be checked with the help of menu Extra configuration > … >
Inputs (or Outputs)
• It is possible to reconfigure or remove preconfigured inputs and outputs
Example: When removing the second burner stage (“---“ in place of N.Q4, for exam-
ple), the 2-stage burner becomes a 1-stage burner.
The configuration diagram shows the types of extension modules required.
Also shown are the inputs and outputs preconfigured in the extension modules. For
plant type H4-5, extension modules RMZ782B(1), RMZ782B(2) and RMZ783B are
used as standard. This can be viewed on the Basic configuration menu, operating lines
Position 1, Position 2 and Position 3.
The type of extension modules used can be changed, but in that case, all inputs and
outputs of the changed module must be reconfigured.
Type of
module
Input variable Terminal Designation in diagram
RMZ783B
Primary flow sensor
X1 A3.X1
Storage tank sensor at
the top
X2 A3.X2
RMZ782B(1) Flow sensor X1 A2.X1
RMZ782B(2) Flow sensor X1 A2.X1
Type of
module
Output variable Terminal Designation in diagram
3-position primary mixing
valve
Q1 and Q2 A3.Q1/Q2
RMZ783B
Primary pump Q5 A3.Q5
3-position mixing valve
Q1 and Q2 A2.Q1/Q2
RMZ782B(1)
Heating circuit pump Q3 A2.Q3
3-position mixing valve
Q1 and Q2 A2.Q1/Q2
RMZ782B(2)
Heating circuit pump Q3 A2.Q3
• “A2.“ in the table denotes extension module RMZ782B, “A3“ denotes extension
module RMZ783B.
• If required, additional inputs and outputs can be assigned to the free inputs and
outputs via “Extra configuration”
• The inputs and outputs can be checked with the help of menu Extra configuration > … >
Inputs (or Outputs)
• Additional function blocks can be activated via “Extra configuration“
3.2.5 Extension modules
RMH760B
RMZ78… RMZ78…
3133Z03
RMZ78…
RMZ78…
A maximum of 4 extension modules can be connected to the RMH760B.
Prior to attaching an extension module, the plant must be disconnected from power.
The order in which the extension modules are fitted is not mandatory but must corre-
spond to the setting made on the controller.
Notes
Extension modules
Inputs
Outputs
Notes
Note
Order