6.9.23 28h: Operating mode
The operating mode can be set via parameter 28h.
Parameter address
28h
Description
operating mode
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
0
Data content
0: Absolute position
1: Difference
2: Modulo (360° angle display)
3: Alpha-numeric display
6.9.24 30h: Display in the 2
nd
row
Via parameter 30h the display of the 2
nd
row of the display unit is controlled. The setting is
not effective in the "Display" operating mode.
Parameter address
30h
Description
controls the display of the 2
nd
row of the display unit
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
0
Data content
0: Set point or differential value (depending on mode, see chapter
4.1.1: Position-bound operating modes)
1: Off