Communication via SIKONETZ 5
AP10S
Date: 04.09.2017 Art. No. 87826 Mod. status 269/17 Page 26 of 48
6.9 Parameter description
6.9.1 00h: Node address
Setting of the SIKONETZ5 node address.
Changes become active only after restart of the device.
Parameter address
00h
Description
node address
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
31
Data content
1 … 127
6.9.2 01h: Baud rate
Setting of the SIKONETZ5 baud rate.
Changes become active only after restart of the device.
Parameter address
01h
Description
Baud rate of the RS485 interface
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
57600 kBaud
Data content
0 = 19200
1 = 57600
2 = 115200
6.9.3 02h: Bus Timeout
See chapter 6.7.1: Bus-Timeout.
Parameter address
02h
Description
Indication of bus timeout in x100 ms
Access
rw
EEPROM
yes
Programming mode
yes
Data type
UNSIGNED 8
Default
0
Data content
0 … 20