Communication via SIKONETZ 5
AP10S
Date: 04.09.2017 Art. No. 87826 Mod. status 269/17 Page 46 of 48
6.9.55 FBh: Set point1
The current set point1 (alpha-numeric display operating mode) can be written and read via
address FBh (see chapter 4.1.2).
Parameter address
FBh
Description
Set point1
Access
rw
EEPROM
no
Programming mode
no
Data type
UNSIGNED 32
Default
-
Data content
0h … FFFFFFFFh
6.9.56 FCh: Differential value
The differential value can be read via parameter FCh. Formation of the differential value is set
via parameter 34h: Formation of the differential value.
Parameter address
FCh
Description
Differential value: Deviation between actual and target positions
Access
ro
EEPROM
no
Programming mode
no
Data type
SIGNED 32
Default
-
Data content
MS500H: -65536000 65536000
GS04: -5242880 5242880
6.9.57 FDh: Error telegram
Illegal entries are answered with an error telegram.
An error telegram consists of the parameter address FDh and an error code (see chapter 6.5:
Error telegram).
Parameter address
FDh
Description
Error telegram
Access
-
EEPROM
no
Programming mode
no
Data type
UNSIGNED 32
Default
-
Data content
see chapter 6.5: Error telegram